Pentair error codes
- Priming Failure Pump didn't prime within the Max Priming Duration
- Overheat Drive above 130掳F: pump slows down to cool
- Over Current Drive overloaded or motor electrical problem
- Flow Limit (warning) Pump hit the max flow set in Min/Max
- Internal Error Motor control software error
- Over Voltage Supply voltage too high, or water spinning the pump
- Power Out Incoming supply voltage too low
- Pressure Limit (warning) Pump hit the max system pressure set in Min/Max
- Speed Limit (warning) Pump hit the max speed set in Min/Max
- ERR PS Water pressure switch open: not enough water flowing through the heater
- ERR IGN Ignition failure: the control module could not light the heater
- ERR HLS High limit switch open: water hotter than 135掳F off the first pass
- ERR AFS Air flow switch open: blower off or its air is restricted
- ERR AGS Automatic gas shutoff open: water off the second pass over 140掳F
- ERR SFS Stack flue too hot (over 480掳F)
- E01 / 126 Water temperature sensor open (E01) or shorted (126)
- E05 / E06 Stack flue sensor open (E05) or shorted (E06)
- SERVICE HEATER The fault is in the heater or its controls
- SERVICE SYSTEM Too little water is reaching the heater