Cell efficiency reduced or inspection due (flashing); greatly reduced (steady)
Hayward AquaRiteWhat it means
Flashing: cell efficiency is reduced, or it's time for the regular inspection (about every 500 hours). Steady: efficiency is greatly reduced and the AquaRite has stopped producing chlorine.
Check this first
- Turn off power to the AquaRite
- Remove and inspect the cell for scale or debris
- Flush with a hose; use a plastic or wood tool, never metal
- Hold the Diagnostic button 3 seconds to reset the reminder
When to call a pro
If it stays on after a thorough cleaning, the cell may be worn out and need replacing.
Usual part
Hayward TurboCell (match your model)