Pool heaters error codes
- Water Sw Open Water pressure switch open: not enough flow
- Ignition Lockout No pilot sensed, or pilot went out during main-burner trial
- Rollout Sw Open Flame rollout switch open
- Clock/Fireman Sw Open circuit at the time clock or fireman switch
- Flame w/o CFH Flame sensed with the pilot and main valves ordered shut
- Hi Limit 1 / Hi Limit 2 is open A high limit switch opened
- Low Temp Lockout Water colder than 36掳F
- Sensor Failure / Open / Short Thermistor problem
- Vent/Field Sw #1 Vent spill switch (or field switch 1) open
- LP Air too cold for the heat pump (not the gas heater's LO)
- CHECK FLOW Not enough water flow to the heater
- FAULT- CHECK IGN CONTROL Ignition problem (6 possible causes)
- FAULT - HIGH FLUE TEMPERATURE Flue temperature limit faulted
- FAULT- HIGH LIMIT Water past the internal limit, or a limit switch faulted
- FAULT- OPEN WATER SENSOR / SHORTED H2O SENSOR Water temperature sensor failed or wiring faulty
- FAULT- PUMP Status, not a fault: Maintain Temp mode with the pump off
- Ignition control LED flashes 1 flash air flow, 2 flame without call for heat, 3 lockout, steady control fault
- ERR PS Water pressure switch open: not enough water flowing through the heater
- ERR IGN Ignition failure: the control module could not light the heater
- ERR HLS High limit switch open: water hotter than 135掳F off the first pass
- ERR AFS Air flow switch open: blower off or its air is restricted
- ERR AGS Automatic gas shutoff open: water off the second pass over 140掳F
- ERR SFS Stack flue too hot (over 480掳F)
- E01 / 126 Water temperature sensor open (E01) or shorted (126)
- E05 / E06 Stack flue sensor open (E05) or shorted (E06)
- SERVICE HEATER The fault is in the heater or its controls
- SERVICE SYSTEM Too little water is reaching the heater
- LO One of 3 safety switches faulted: water pressure, vent pressure or temperature limit
- IF Ignition failure
- HF Flame present while the gas valve has no power
- AO / AC Blower vacuum switch open (AO) or closed (AC)
- BD / EE Bad control board (BD can also be a secondary high-voltage fault)
- CE Lost communication between control module and display
- HS Return water too hot, or heated too fast
- IO Ignitor circuit open
- PF Low voltage or reversed polarity
- SB Failed keypad
- SF Temperature sensor (thermistor) failed